1.0.1.43
		 - 27feb2014, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 
		3.2
		
			- fixed writebyte for BioDAQ driver (BaslerSCIEjector.dll)
 
		 
		
		1.0.1.42
		 - 08apr2013, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 
		3.2
		
		
		1.0.1.41
		 - 18jan2013, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.3
		
		
		
		1.0.1.40
		 - 13jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.3
		
		
		1.0.1.39
		 - 13jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2
		
			- add biodaq to BaslersciEjector.dll to access advantech devices, selectable by parameter
 
		 
		
		1.0.1.38
		 - 04jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2
		
			- inhibitPylonTerminate parameter introduced, will help to coexist different pylon drivers on the same Scorpion profile
 
		 
				
		1.0.1.37 - 31may2011, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.0 
		
			- special build for USB advantech card
 
		 
		
		
		1.0.1.36 - 24nov2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- image feed fixed in linegrabbing multi-chunk mode
 
		 
		
		
		1.0.1.34 - 05nov2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- major rewrite of buffers for snapshot and continuous in linegrabbing mode
 
			- optional timestamp embedding in the image
 
		 
		
		
		1.0.1.33 - 02nov2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- preventing old buffer content display for linecounter grab snapshot mode
 
		 
		
		
		1.0.1.32 - 27oct2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- for Color Runner frameheight in linemode up to 30K lines in full resolution
 
		 
		
		1.0.1.31 - 12oct2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- height setting fixed for linegrabbing mode
 
		 
		
		1.0.1.30 - 06oct2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.2 
		
			- beta pylon 2.2 support
 
			- parameter configuration via genicam, by using a listview
 
		 
		
		
		1.0.1.29 - 15sep2010, min Scorpion Vision Software version: 
		8.0.0.441, Pylon Version: 2.1 
		
			- immediate response of set property 'ExposureTime', 'LineRate' 
			and 'Continous'
 
			- ignores ejector commands past current position
 
			- initial Grab command not nessesary after setting property 'Continous=1'
 
		 
		
		1.0.1.28 
			- 28apr2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.1 
		
			- check for supported exposure modes
 
		 
		1.0.1.27 
			- 03mar2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.1 
		
			- added ejector mask command
 
			- added ejector callback command
 
		 
		1.0.1.26 
			- 18nov2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- in line counter mode image size can be up to 100000 lines
 
			- fixed validation of network parameters
 
			- when line trigger enabled, set line rate to ResultingLineRateAbs
 
		 
		1.0.1.25 
			- 09nov2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- allow to select line start trigger mode without frame start trigger mode
 
			- log in to file setting is not persistent
 
		 
		1.0.1.24 
			- 01sep2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- new parameters for monochrome cameras:
 
			
				- gain tap 1 - additional gain for the even numbered pixels
 
				- gain tap 2 - additional gain for the odd numbered pixes
 
				- black level tap 1 - additional black level adjustment for the even numbered pixels
 
				- black level tap 2 - additional black level adjustment for the odd numbered pixels
 
			 
			- correctly recognize the camera when user id is assigned
 
		 
		1.0.1.23 
			- 19jun2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- Setting linerate to max value when line trigger mode is used
 
		 
		1.0.1.22 
			- 17jun2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- Black Level and Gain moved to Analog tab
 
			- New tab for Input/Output Lines configuration
 
			- Read Input lines: getProperty("Inputs")
 
			- Write to Output lines: setProperty("Outputs", 3)
 
			- Compiles with Pylon 2.0 and Pylon 2.1
 
		 
        
		1.0.1.21
			 - 28may2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1 
		
			- compiled against Pylon 2.1
 
			- shaft encoder support
 
		 
		1.0.1.20
			 - 20mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- do not skip delayed lines
 
			- no limit for delay parameter
 
			- do not allow open camera properties dialog when continuous grab 
			set
 
		 
		1.0.1.19 - 17mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- overlap can be 100% of image height
 
			- delay parameter specified in chunks (one chunk = lines per 
			trigger)
 
		 
		1.0.1.18 - 13mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- messages for parameter validation errors in configuration dialog, Pylon Version: 2.0
 
		 
		1.0.1.17 - 11mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- ejector static mode introduced
 
			- to enable/disable: setProperty('EjectorStaticMode', 1/0)
 
			- to set static command: setProperty('EjectorStaticCommand 
			EFEFEFEF', 0) 
 
			- fixed correct return to freerun acquisition back from line/frame 
			trigger mode
 
		 
		1.0.1.16 - 25feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- line mode grabs in frames of lines trigger resolution size
 
		 
		1.0.1.15 - 24feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
		
			
				- byte order for the ejector reversed 
 
				- when there is no ejector command for a certain line - zeroes are issued 
		(subject to invert setting)
 
		 
		1.0.1.14 - 24feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
			
				- fix for monochrome cameras - did not initialize because color 
			parameters were attempted to set 
 
			 
		1.0.1.13 - 17feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- horizontal decimation parameter
 
		 
		1.0.1.12 - 09feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- invert ejector command setting in dialog
 
			- or'ing ejector commands instead of assigning (thus possibility to 
			come back to already issued commands)
 
		 
		1.0.1.11 - 29jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- small updates to the settings dialog
 
		 
		1.0.0.10 - 27jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- conditional compilation to advantech libraries
 
			- includes and project files moved to separate folders
 
			- fixed first frame mixture when using overlap
 
		 
		1.0.0.9 - 20jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0 
		
			- advantech ejector control incorporated in the driver
 
		 
		1.0.0.3 - 06Nov2008, min Scorpion Vision Software version: 6.x.x.x, Pylon Version: 2.0 
		
			- color camera support (ruL2098-10gc)
   
		 
		 |