1.0.1.43 - 27feb2014, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 3.2
  • fixed writebyte for BioDAQ driver (BaslerSCIEjector.dll)
1.0.1.42 - 08apr2013, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 3.2
  • pylon 3.2 support
1.0.1.41 - 18jan2013, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.3
  • racer camera support
1.0.1.40 - 13jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.3
  • pylon 2.3 support
1.0.1.39 - 13jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2
  • add biodaq to BaslersciEjector.dll to access advantech devices, selectable by parameter
1.0.1.38 - 04jan2012, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2
  • inhibitPylonTerminate parameter introduced, will help to coexist different pylon drivers on the same Scorpion profile

1.0.1.37 - 31may2011, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.0

  • special build for USB advantech card

1.0.1.36 - 24nov2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • image feed fixed in linegrabbing multi-chunk mode

1.0.1.34 - 05nov2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • major rewrite of buffers for snapshot and continuous in linegrabbing mode
  • optional timestamp embedding in the image

1.0.1.33 - 02nov2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • preventing old buffer content display for linecounter grab snapshot mode

1.0.1.32 - 27oct2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • for Color Runner frameheight in linemode up to 30K lines in full resolution

1.0.1.31 - 12oct2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • height setting fixed for linegrabbing mode

1.0.1.30 - 06oct2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.2

  • beta pylon 2.2 support
  • parameter configuration via genicam, by using a listview

1.0.1.29 - 15sep2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.1

  • immediate response of set property 'ExposureTime', 'LineRate' and 'Continous'
  • ignores ejector commands past current position
  • initial Grab command not nessesary after setting property 'Continous=1'

1.0.1.28 - 28apr2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.1

  • check for supported exposure modes

1.0.1.27 - 03mar2010, min Scorpion Vision Software version: 8.0.0.441, Pylon Version: 2.1

  • added ejector mask command
  • added ejector callback command

1.0.1.26 - 18nov2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • in line counter mode image size can be up to 100000 lines
  • fixed validation of network parameters
  • when line trigger enabled, set line rate to ResultingLineRateAbs

1.0.1.25 - 09nov2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • allow to select line start trigger mode without frame start trigger mode
  • log in to file setting is not persistent

1.0.1.24 - 01sep2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • new parameters for monochrome cameras:
    • gain tap 1 - additional gain for the even numbered pixels
    • gain tap 2 - additional gain for the odd numbered pixes
    • black level tap 1 - additional black level adjustment for the even numbered pixels
    • black level tap 2 - additional black level adjustment for the odd numbered pixels
  • correctly recognize the camera when user id is assigned

1.0.1.23 - 19jun2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • Setting linerate to max value when line trigger mode is used

1.0.1.22 - 17jun2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • Black Level and Gain moved to Analog tab
  • New tab for Input/Output Lines configuration
  • Read Input lines: getProperty("Inputs")
  • Write to Output lines: setProperty("Outputs", 3)
  • Compiles with Pylon 2.0 and Pylon 2.1

1.0.1.21 - 28may2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.1

  • compiled against Pylon 2.1
  • shaft encoder support

1.0.1.20 - 20mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • do not skip delayed lines
  • no limit for delay parameter
  • do not allow open camera properties dialog when continuous grab set

1.0.1.19 - 17mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • overlap can be 100% of image height
  • delay parameter specified in chunks (one chunk = lines per trigger)

1.0.1.18 - 13mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • messages for parameter validation errors in configuration dialog, Pylon Version: 2.0

1.0.1.17 - 11mar2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • ejector static mode introduced
  • to enable/disable: setProperty('EjectorStaticMode', 1/0)
  • to set static command: setProperty('EjectorStaticCommand EFEFEFEF', 0)
  • fixed correct return to freerun acquisition back from line/frame trigger mode

1.0.1.16 - 25feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • line mode grabs in frames of lines trigger resolution size

1.0.1.15 - 24feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • byte order for the ejector reversed
  • when there is no ejector command for a certain line - zeroes are issued (subject to invert setting)

1.0.1.14 - 24feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • fix for monochrome cameras - did not initialize because color parameters were attempted to set

1.0.1.13 - 17feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • horizontal decimation parameter

1.0.1.12 - 09feb2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • invert ejector command setting in dialog
  • or'ing ejector commands instead of assigning (thus possibility to come back to already issued commands)

1.0.1.11 - 29jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • small updates to the settings dialog

1.0.0.10 - 27jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • conditional compilation to advantech libraries
  • includes and project files moved to separate folders
  • fixed first frame mixture when using overlap

1.0.0.9 - 20jan2009, min Scorpion Vision Software version: 7.x.x.x, Pylon Version: 2.0

  • advantech ejector control incorporated in the driver

1.0.0.3 - 06Nov2008, min Scorpion Vision Software version: 6.x.x.x, Pylon Version: 2.0

  • color camera support (ruL2098-10gc)
     